Replacing a Failed Environmental Status Module
007-4834-001 55
Replacing a Failed Environmental Status Module
When TPSSM instructs you to replace a failed environmental status module, read
“Environmental Status Modules (ESMs)” on page 19, and then follow the steps in this
section.
Caution: Electrostatic discharge can damage sensitive components. Use a grounded
wrist strap or other antistatic precautions before handling enclosure components.
1. Check TPSSM for instructions on environmental status module failure recovery
procedures. Follow any instructions provided before you proceed.
2. Unpack the new environmental status module. Set the new module on a dry, level
surface near the enclosure. Save all packing materials in case you need to return the
module.
3. Review all documentation shipped with the new environmental status module for
updated replacement procedures and other information. If necessary, modify the
remaining steps to meet the system requirements. Kits often contain the most
current servicing information. If the kit instructions conflict with those in this
procedure, follow the kit instructions.
4. Locate the failed environmental status module (its fault indicator should be on).
5. Disconnect the Fibre Channel cables from the SFP transceivers in the failed module,
and then remove the SFP transceivers (see “Replacing an SFP Transceiver” on
page 51). Label each cable to ensure that all cables are properly reconnected to the
new module.
Caution: Bending or damaging Fibre Channel cables can result in degraded
performance or data loss. Fibre Channel cables are fragile. Do not pinch the cables
with tie wraps, step on them, or bend at them at sharp angles.
6. Wearing antistatic protection, push down on the latch centered above the
environmental status module. The levers will pop out of the locked position (see
Figure 4-8).
7. Grasp the pull-rings and pull on the levers to remove the failed module.
8. Wearing antistatic protection, slide the new environmental status module all the
way into the empty slot.
!
!