SGI InfiniteStorage 4000 Series Betriebsanweisung Seite 61

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 122
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 60
007-4834-001 43
Chapter 4
4. Replacing Enclosure Components
This chapter describes how to replace each component in the enclosure in the following
sections:
“Replacing a Failed Disk Drive” on page 43
“Replacing a Failed Power/Fan Module” on page 46
“Replacing a Failed RAID Controller Module” on page 49
“Replacing a Failed Environmental Status Module” on page 55
“Upgrading Drives” on page 57
“Adding Expansion Enclosures” on page 61
Replacing a Failed Disk Drive
When the storage management software (TPSSM) instructs you to replace a failed drive
module, read “The Disk Drives” on page 17, and then follow the steps in this section.
To prevent loss of access to data, remove only a failed drive that has a drive Fault light
on and the drive Service Action Allowed light on, or has a Failed status in the storage
management software.
Warning: Electrostatic discharge can damage sensitive components. Use a grounded
wrist strap or other antistatic precautions before handling enclosure components.
Seitenansicht 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 121 122

Kommentare zu diesen Handbüchern

Keine Kommentare