Seitenansicht 78
PCIe Card Installation Steps
007-5759-001 55
PCIe Card Installation Steps
A PCIe-support riser card has already been pre-installed into each of the four serverboards. The
riser accepts only low-profile PCIe option boards. The board must be less than 5.9 inches (15 cm)
in length.
Perform the following steps to install a low-profile PCIe add-on card:
1. Power off the server.
2. Use a phillips-head screwdriver to remove the retention screw to the left of the PCIe slot (see
Figure 6-6 for an example).
3. Slide the rectangular PCIe retention tab to the left.
Figure 6-6 PCIe Retention Screw and Tab
4. Grasp the serverboard’s circular handles at either end and simultaneously push inward on the
tab beneath each handle, see Figure 6-7 on page 56 for an example.
5. Pull the serverboard tray out until the PCIe riser card is fully visible.
6. Remove the PCIe slot shield on the serverboard rear panel.
7. Insert the add-on card into the riser card’s PCIe slot.
8. Secure the add-on card with the sliding rectangular lock tab and replace the retention screw.