SGI 2400 Wartungshandbuch

Stöbern Sie online oder laden Sie Wartungshandbuch nach Server SGI 2400 herunter. SGI 2400 Technical data Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 22
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
SGI
Tensor Processing Unit (TPU)
XIO Board Introduction
Document Number 007-4222-002
Seitenansicht 0
1 2 3 4 5 6 ... 21 22

Inhaltsverzeichnis

Seite 1 - XIO Board Introduction

SGI™ Tensor Processing Unit (TPU)XIO Board IntroductionDocument Number 007-4222-002

Seite 3

10. TPU XIO Board IntroductionThis document accompanies the SGI Tensor Processing Unit (TPU) XIO board andcontains information about the TPU power req

Seite 4

2TPU XIO Board IntroductionPart VerificationOpen the XT-TPU-ORIGIN-1 box and verify that these components are included:• One SGI TPU XIO board in antis

Seite 5

3Panel Plate and LEDsUnlike most XIO boards, the TPU XIO panel plate has no ports. It contains three roundLEDs. During normal operation, these LEDs il

Seite 6

4TPU XIO Board IntroductionSoftware Installation and ConfigurationIf your system is currently up and running, save yourself time and extra system reboo

Seite 7 - Contents

5Slot SelectionFollow the instructions in this section to select an appropriate XIO slot.•“Slot Selection Rules for Origin 2000 Deskside and SGI 2200

Seite 8

6TPU XIO Board IntroductionFigure 2 I/O Items in the Origin 2000 Deskside ServerBaseIOXIO boardI/O cageMidplaneMiddlecard guideFiller panelRear of Mod

Seite 9 - List of Figures

7Slot Selection Rules for Onyx2 Deskside SystemsEach Onyx2 node board accommodates a maximum of 3 TPU cards. The Onyx2 desksidesystem has 6 XIO slots.

Seite 10

8TPU XIO Board IntroductionFigure 3 I/O Items in the Onyx2 Deskside ServerMidplaneMiddlecard guideCompressionconnector forslot 5Lower cardguideBaseIOB

Seite 11 - 0. TPU XIO Board Introduction

9Slot Selection Rules for Origin 200 Gigachannel ServersThe Origin 200 Gigachannel expansion cabinet has 5 XIO slots, which arenumbered 11–15. A maxim

Seite 12 - Power Requirements

SGI™ Tensor Processing Unit (TPU) XIO Board IntroductionDocument Number 007-4222-002CONTRIBUTORSWritten by Heidi RacanelliIllustrated by Carlin Otto,

Seite 13 - Panel Plate and LEDs

10TPU XIO Board IntroductionThe server installation instructions provide information that can help youdetermine which of the slots are activated.Note:

Seite 14

11Figure 5 I/O Items in Origin 2000 Rackmount, SGI 2400, and SGI 2800 Server ProcessorModuleBaseIOXIO boardI/O cageMidplaneMiddlecard guideFiller pane

Seite 15 - Slot Selection

12TPU XIO Board IntroductionStartupWhen the board is installed and connected, follow the instructions in this section to startoperation.1. Power on th

Seite 16 - TPU XIO Board Introduction

SGI™ Tensor Processing Unit (TPU) XIO Board IntroductionDocument Number 007-4222-002FCC WarningThe equipment described in this guide has been tested a

Seite 17

SGI™ Tensor Processing Unit (TPU) XIO Board IntroductionDocument Number 007-4222-002AttentionCet appareil numérique de la classe A est conforme a la n

Seite 18

SGI™ Tensor Processing Unit (TPU) XIO Board IntroductionDocument Number 007-4222-002Silicon Graphics is a registered trademark and SGI and the SGI log

Seite 20

viiContentsContents viiList of Figures ixTPU XIO Board Introduction 1Part Verification 2Maximum Number of TPU Boards 2Power Requirement

Seite 22

ixList of FiguresFigure 1 Panel Plate and LEDs for the TPU XIO Board 3Figure 2 I/O Items in the Origin 2000 Deskside Server 6Figure 3 I/O Items

Kommentare zu diesen Handbüchern

Keine Kommentare